Services

Accredited inspection of facade performance testing.

beTcs inspects the testing of cladding systems, curtain walling, door, window and skylight assemblies, facade assemblies and sloped glazing, for structural and weather performance, in the laboratory and on site.

Before testing

Advice that prevents a failed test.

  • Advice on the proposed test schedule and PMU configuration
  • Scrutiny of an overseas facility's accreditation, credentials and scope
  • Review of the facility's equipment and instrumentation for operability, range, calibration and accuracy
  • Confirmation that test procedures, parameters and PMU configuration are agreed by all parties
01 · Laboratory

Laboratory test witnessing and supervision

We witness and supervise performance testing of curtain wall prototypes, and of windows and sliding doors, at Australian and overseas laboratories. We make sure the test is run to the specified standard and agreed parameters, analyse the results independently, and issue a NATA-accredited inspection report.

Curtain wall prototypes

AS/NZS 4284 (SIROWET)ASTM E283ASTM E330ASTM E331ASTM E547BS EN 12152BS EN 12153BS EN 12154BS EN 12155BS EN 12179BS EN 12600BS EN 13116BS EN 14019AAMA 501.1AAMA 501.4AAMA 501.5CWCT TN75 & TN76

Windows and sliding doors

AS/NZS 4420.1 for AS 2047BS EN 1026BS EN 1027BS EN 12207BS EN 12210BS EN 12211BS EN 13049
Faceted curtain wall performance mock-up with triangular glazing in a test laboratory
02 · Impact

Impact performance testing

CWCT Technical Notes 75 and 76 set out a test method and classification system for the impact performance of cladding panels, under safety and serviceability conditions. They matter most where cladding is within public reach and accidental impact or misuse is likely.

beTcs holds the specified soft- and hard-body impactors to ISO 7892. At 55 Pitt Street, Sydney, we carried out almost 200 impacts across numerous terracotta tile profiles.

CWCT TN75CWCT TN76BS EN 12600BS EN 13049BS EN 14019ISO 7892 impactors
Steel ball hard-body impactor suspended in front of terracotta tile cladding
Hard-body impactor set up on a terracotta tile, 55 Pitt Street
Soft-body bag impactor suspended beside a terracotta sunshade sample
Soft-body impactor set up on terracotta sunshade sample, 55 Pitt Street
Water penetration field test of an installed curtain wall from an elevated work platform
Field water test of an installed curtain wall
03 · Site

Field testing of installed facades

AAMA 501.2 is the widely accepted method for quality assurance and water penetration checks of installed curtain walls and sloped glazing. AAMA 503 and BS EN 13051 are more exacting means of on-site assessment.

FGIA/AAMA 501.2FGIA/AAMA 503BS EN 13051
04 · Compliance

NCC weatherproofing verification

The National Construction Code specifies Verification Methods F3V1 (Volume One) and H2V1 (Volume Two) to evaluate the weatherproofing of direct-fix cladding, cavity and unique wall systems. They provide a means to verify compliance with Performance Requirements F3P1 and H2P2 for water penetration through an external wall.

NCC Volume One F3V1NCC Volume Two H2V1

Bring us in before the test schedule is fixed.

Independent advice is worth most before the PMU is designed and the laboratory is booked.

Discuss your project